0102030405
Adhesive Type Vent Membrane by Leading China Suppliers | Quality Factory Manufacturing Solutions
Product Technical Data Sheet
| PRODUCT NAME | Adhesive Type Vent Membrane |
| PRODUCT MODEL | ZZPIP-E90H30+5610_8x4 |
| PRODUCT DIAGRAM |
|
| MEMBRANE MODEL | ZZPIP-E90H30 |
| ADHESIVE MODEL | 5610 |
| PRODUCT DIMENSION |
Thickness: 0.2 ± 0.05 mm
Inner Diameter: 4 ± 0.2 mm
Outer Diameter: 8 ± 0.2 mm
|
Product Properties
| Physical Properties | Referred Test Standard | Unit | Typical Data |
|---|---|---|---|
| Membrane Color | / | / | White |
| Membrane Construction | / | / | PTFE / PET non-woven |
| Membrane Surface Property | / | / | Hydrophobic |
| Thickness (Membrane & Adhesive) | ASTM D374 | mm | 0.2 ± 0.05 |
| Adhesive Strength (180° peel on SS Panel) | ASTM D3330 | N/inch | 16.9 |
| Min Air Flow Rate | ASTM D737 | ml/min@ 7Kpa | >1500 |
| Typical Air Flow Rate | ASTM D737 | ml/min@ 7Kpa | 2300 |
| Water Entry Pressure | ASTM D751 | KPa for 30 sec | >10 |
| IP Rating | IEC 60529 | / | IP68 |
| Moisture Permeability | ASTM E96 | g/m²/24h | >5000 |
| Oleophobic Grade | AATCC 118 | Grade | NA |
| Operation Temperature | IEC 60068-2-14 | ℃ | -40℃ ~ 125℃ |
| ROHS | IEC 62321 | / | Meet ROHS Requirements |
| PFOA & PFOS | US EPA 3550C & US EPA 8321B | / | PFOA & PFOS Free |
Application
This series of membranes could be used in Automotive Lamps, Automotive Sensitive Electronics, Outdoor Lighting, Outdoor Electronic Devices, Household Electrical and Electronics etc.
The membrane can balance inside/outside pressure differentials of sealed enclosures while blocking contaminants, which could increase components’ reliability and extend their service life.
Shelf Life:
Shelf life is two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80° F (27° C) and 60% RH.
Handling and Installation Guidelines
Note: The following content is only applicable to manual installation plan. If you need to know the automatic installation plan, please contact ZZPIP sales staff.
Handling & Dispensing Guidelines
Handling Guidelines:
- Operators should wear latex and powder-free gloves or fingercots when handling adhesive vents.
- Avoid direct contact with the active venting area.
- Keep all sharp or jagged items away from the ePTFE membrane.
- To prevent damage to the product, do not pry the diaphragm directly from the release film.
- For manual dispensing, roll the liner under the vent, slowly over an edge, until the vent extends beyond the liner and becomes accessible. Blunt-edged tweezers may be used to remove the vent gently from the liner.
Installation Guidelines
-
Preparation
- Ensure that the enclosure’s mounting surfaces are smooth, clean and free from oils, particles or other contaminants; free from jagged or rough edges that could damage the vent.
- Isopropyl alcohol can be used to clean the enclosure’s mounting surface.
- Ensure that the enclosure’s mounting surface is dry prior to vent installation.
-
Positioning
- The product should be mounted only on interior housing surfaces, ensuring the e-PTFE membrane side facing the external environment.
- In order to achieve the best performance, the film should be installed on a flat, vertical surface to avoid liquid or other contaminants on the surface of the film.
-
Installation
- Apply firm finger force at least twice in a circular motion directly to the adhesive ring area to seal the vent to the housing, being careful not to touch center of the vent area.
- Ensure the entire adhesive ring is pressed against the surface.
- Allow 24 hours cure time before using or testing.
-
Note
- Once installed, vents should not be repositioned.
- Vents will be damaged when they are removed from the mounting surface.
Disclaimer Note:
All data above are typical data for the membrane raw material, for reference only, and should not be used as special data for outgoing quality control. All technical information and advice given here is based on ZZPIP previous experiences and test results. ZZPIP gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.
All data above are typical data for the membrane raw material, for reference only, and should not be used as special data for outgoing quality control. All technical information and advice given here is based on ZZPIP previous experiences and test results. ZZPIP gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.
Frequently Asked Questions
What are the typical applications for the Adhesive Type Vent Membrane?
This series of membranes is ideal for Automotive Lamps, Automotive Sensitive Electronics, Outdoor Lighting, Outdoor Electronic Devices, and Household Electrical and Electronics. They help balance inside and outside pressure differentials of sealed enclosures while blocking contaminants.
What is the IP rating and air flow rate of the ZZPIP-E90H30+5610_8x4 model?
The membrane has an IP rating of IP68 (according to IEC 60529 standards) and features a typical air flow rate of 2300 ml/min @ 7Kpa, with a minimum air flow rate of >1500 ml/min @ 7Kpa.
How should the mounting surface be prepared before installation?
The enclosure's mounting surfaces must be smooth, clean, dry, and free from oils, particles, or rough/jagged edges. Isopropyl alcohol can be used to clean the mounting surface prior to applying the vent membrane.
Can the vent membrane be repositioned after it has been installed?
No. Once installed, the vents should not be repositioned. Removing them from the mounting surface will cause damage to the membrane and the adhesive layer.
What is the shelf life and recommended storage conditions?
The product has a shelf life of two years from the date of receipt, provided it is stored in its original packaging in an environment kept below 80° F (27° C) and 60% Relative Humidity (RH).