Non-PFAS Vent Membrane
Membrane Properties:
|
PHYSICAL PROPERTIES |
REFERED TEST STANDARD |
UNIT |
TYPICAL DATA |
|
Membrane Color |
/ |
/ |
White |
|
Membrane Construction |
/ |
/ |
PO/PO nonwoven |
|
Membrane Surface Property |
/ |
/ |
Hydrophobic |
|
Thickness |
ISO 534 |
mm |
0.16±0.05 |
|
Interlayer Bonding Strength (90 degree peel) (90 ) |
Internal Method |
N/inch |
>2 |
|
Min Air Flow Rate |
ASTM D737 ( 1 cm²) |
ml/min/cm²@ 7Kpa |
>300 |
|
Typical Air Flow Rate |
ASTM D737 ( 1 cm²) |
ml/min/cm²@ 7Kpa |
500 |
|
Temporary Water Entry Pressure |
ASTM D751 ( 1 cm²) |
KPa |
>250 |
|
Water Entry Pressure (Dwell 30s) 30 |
ASTM D751 ( 1 cm²) |
KPa for 30 sec |
>200 |
|
IP Rating |
IEC 60529 |
/ |
IP68 |
|
Water Vapor Transmission Rate |
GB/T 12704.2 38℃/50%RH |
g/m2/24h |
>5000 |
|
Oleophobic Grade |
AATCC 118 |
Grade |
NA |
|
Operation Temperature |
IEC 60068-2-14 |
℃ |
-40℃ ~ 120℃ |
|
ROHS |
IEC 62321 |
/ |
Meet ROHS Requirements ( ROHS ) |
|
REACH SVHC |
REACH 1907/2006/EC |
/ |
Meet REACH Requirements ( REACH ) |



Shelf Life: