Snap-In Vent Plug - High-Quality China Suppliers from ZZPIP Factory for Reliable Performance
Product Technical Data Sheet
| PRODUCT NAME | Snap-In Vent Plug |
| PRODUCT MODEL | ZZPIPVent Plug_D17_E10ZO |
| PRODUCT DIAGRAM |
|
| MEMBRANE MODEL | ZZPIPE10ZO |
| APPLICATION FIELD | Chemicals Packaging |
| APPLICATION CHEMICAL | Bleacher, Disinfectant, Amino Acid, Agrochemicals, Live bacterial agent, Thick liquid fertilizer |
Product Properties
| PHYSICAL PROPERTIES | REFERRED TEST STANDARD | UNIT | TYPICAL DATA |
|---|---|---|---|
| Plug Material | / | / | HDPE |
| Plug Color | / | / | White |
| Membrane Construction | / | / | PTFE/PO non-woven |
| Membrane Surface Property | / | / | Oleophobic & Hydrophobic |
| Typical Air Flow Rate | ASTM D737 | ml/min @ 7KPa | 850 |
| Water Entry Pressure | ASTM D751 | KPa dwell 30 sec | ≥80 |
| IP Grade | IEC 60529 | / | IP67/IP68 |
| Moisture Vapor Transmission | ASTM E96 | g/m²/24h | >5000 |
| Oleophobic Grade | AATCC 118 | Grade | ≥7 |
| Service Temperature | IEC 60068-2-14 | ℃ | -40℃ ~ 125℃ |
| ROHS | IEC 62321 | / | Meet ROHS Requirements |
| PFOA & PFOS | US EPA 3550C & US EPA 8321B | / | PFOA & PFOS Free |
Application
This series of vent plug could equalize the pressure differentials of chemical containers which caused by temperature difference, altitude changes and releasing/consuming gases, in order to prevent container deformation and liquid leakage.
The vent plugs can be used in breathable cap products for chemicals packaging containers, and be suitable for High-concentration Hazardous Chemicals, Low-concentration Household Chemicals, Agricultural Chemicals and other Special Chemicals.
The vent plugs can be used in breathable cap products for chemicals packaging containers, and be suitable for High-concentration Hazardous Chemicals, Low-concentration Household Chemicals, Agricultural Chemicals and other Special Chemicals.
Shelf Life:
Shelf life is two years from the date of receipt for this product as long as this product is stored in its original packaging in an environment below 80° F (27° C) and 60% RH.
Note: All data above are typical data for the membrane raw material, for reference only, and should not be used as special data for outgoing quality control.
All technical information and advice given here is based on ZZPIP previous experiences and test results. ZZPIP gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.
All technical information and advice given here is based on ZZPIP previous experiences and test results. ZZPIP gives this information to the best of its knowledge, but assumes no legal responsibility. Customers are asked to check the suitability and usability in the specific application, since the performance of the product can only be judged when all necessary operating data are available.
Frequently Asked Questions
Q
What is the primary function of the Snap-In Vent Plug?
The Snap-In Vent Plug is designed to equalize pressure differentials in chemical containers caused by temperature fluctuations, altitude changes, and the release or consumption of gases. This effectively prevents container deformation and liquid leakage.
Q
Which types of chemicals is this vent plug compatible with?
It is suitable for a wide range of chemicals including high-concentration hazardous chemicals, low-concentration household chemicals, agricultural chemicals, bleachers, disinfectants, amino acids, live bacterial agents, and thick liquid fertilizers.
Q
What material is used for the venting membrane and plug?
The plug is made of High-Density Polyethylene (HDPE), and the venting membrane features a PTFE/PO non-woven construction with oleophobic and hydrophobic surface properties.
Q
What are the storage requirements to guarantee the 2-year shelf life?
The product must be stored in its original packaging in an environment kept below 80°F (27°C) and under 60% relative humidity (RH).
Q
Does this vent plug comply with international environmental regulations?
Yes, the plug meets RoHS requirements according to IEC 62321 standards and is certified PFOA & PFOS free under US EPA 3550C and US EPA 8321B testing methods.